- Stock: In Stock
- Product code: Product cr5928
This offer ends in:
- Frequency range: from 100 kHz to 6 GHz.
- Display: color touchscreen with a diagonal of 4.0 inches.
- The battery provides up to 2 hours of continuous operation when fully charged.
- Two modes of operation: normal and ultra mode.
- Configuration: bandpass filter and attenuator.
- Signal Generator: Outputs sine/square waves.
- USB control and automatic self-calibration.
Description of the TinySA Ultra spectrum analyzer
Portable spectrum analyzer with a frequency range from 100 kHz to 6 GHz. This unit features a four-inch touch resistive color display that displays the full frequency range at 450 scan points, and includes a rechargeable battery that provides up to two hours of portable operation. In addition, the analyzer works in two modes: normal and ultra mode. In addition, the TinySA Ultra has many built-in configuration options, including a bandpass filter and a stepped input attenuator. The maximum input level of the TinySA is +6 dBm. When the tinySA Ultra is not being used as a spectrum analyzer, it can also be used as a sine wave or square wave generator. The analyzer can be fully controlled by a PC via a USB cable. It also features automatic self-testing and self-calibration with a built-in signal generator.
Specifications
- Frequency range from 100 kHz to 800 MHz in normal mode and up to 6 GHz in ULTRA mode
- 50 ohm input impedance when the attenuator is on 10dB or more
- Adjustable manual or automatic signal input attenuator with a range of 0 dB to 31 dB in 1 dB steps
- The maximum input level of signals is +10 dBm with the attenuator turned off
- The maximum short-term level is +20 dBm with a 30 dB attenuator
- Recommended maximum input power is +5 dBm with the attenuator operating in automatic mode
- For the most correct measurements, observe the signal level at the input no higher than -25dBm
- Compression point for measuring intermodulation distortions of the 3rd order (IIP3) +15dBm with the attenuator off
- 1dB compression point at -1dBm with the attenuator off
- Resolution of the power detector is 0.5 dB. Linearity depending on frequency +/-2 dB
- The absolute accuracy of the power level detector after calibration is +/-2 dB
- Built-in 20dB LNA LNA with a noise level of 5dB
- Lowest noticeable signal without LNA at 30 MHz using a 30 kHz resolution bandwidth -102 dBm
- Lowest noticeable signal from LNA at 30 MHz using 200 Hz resolution bandwidth -145 dBm
- Frequency precision equal to the selected bandwidth resolution
- Phase noise -90dB/Hz at 100 kHz offset and -120dB/Hz at 1 MHz offset
- Dynamic range when using a 30 kHz resolution bandwidth of 70 dB
- Permissive filters 0.2, 1, 3, 10, 30, 100, 300, 600 and 850 kHz
- Scan permission 51, 101, 145, 290 or 450 points
- Scanning speed over 1000 points per second
- Automatic optimization of actual scan points to ensure full scan range coverage regardless of selected bandwidth resolution
- Headphone output for listening to a demodulated signal (AM only)
Generator of standard signals:
- A sinusoidal signal with a level of harmonics less than -40dB in the range from 100 kHz to 800 MHz
- The output signal level with a step of 1dB in the range from -113dBm to -18dBm
- Up to 800 MHz, you can choose 2 options for the accuracy of the generation according to the output signal:
- 1) Clean signal: meander up to 4.4GHz with coarse frequency tuning and low accuracy of output signal levels
- 2) High-precision mode: maximum suppression of harmonics up to 5.4GHz with good frequency resolution up to 800MHz, accurate signal levels at the generator output
- Output level accuracy +/- 2 dB up to 800 MHz in the range of -72 dBm to -18 dBm, less accuracy below -72 dBm, even less accuracy below -110 dBm
- Frequency range from 44Hz to 800 MHz
- Separate settings by modulating signal for AM and FM from 50 Hz to 5 kHz (AM) or 1 kHz (FM) or FM mode in selected band
- Modulation depth from 10% to 100%
- FM frequency deviation from 1 kHz to 300 kHz
- Calibration generator: meander generator with an output level of -35.6dBm. Connected to the CAL output. Frequencies fixed at 1 MHz, 2 MHz, 4 MHz, 10 MHz, 15 MHz or 30 MHz
Battery characteristics:
- Charging time is approximately 1 hour at a current of 500mA.
- Operating time on a fully charged battery is approximately 2 hours.
Complete set:
- TinySA Ultra (with 3000mAh battery) – 1 pc.
- USB Type-C data cable - 1 pc
- Cable 30cm ALSR100SMA – 2 pcs
- Adapter SMA female -SMA female - 1 pc
- Telescopic antenna - 1 pc
- Strap with stylus - 1 pc